Characteristics
Main range of product Zelio Relayseries name Universalproduct or component type Plug-in relaydevice short name RUMcontacts type and composition 3 C/O[Uc] control circuit voltage 48 V AC[Ithe] conventional enclosed thermal current 10 A at -40...55 °Cstatus LED Withcontrol type Lockable test buttonutilisation coefficient 20 %Complementary shape of pin Flat[Ui] rated insulation voltage 250 V conforming to IEC300 V conforming to UL300 V conforming to CSA[Uimp] rated impulse withstand voltage 4 kV (1.2/50 µs)contacts material AgNi[Ie] rated operational current 10 A at 28 V DC (NO) conforming to IEC10 A at 250 V AC (NO) conforming to IEC5 A at 28 V DC (NC) conforming to IEC5 A at 250 V AC (NC) conforming to IEC10 A at 30 V DC conforming to UL10 A at 277 V AC conforming to UL10 A at 30 V DC conforming to CSA10 A at 277 V AC (same polarity) conforming to CSAmaximum switching voltage 250 V conforming to IECResistive rated load 10 A at 250 V AC10 A at 28 V DCmaximum switching capacity 2500 VA/280 Wminimum switching capacity 170 mW at 10 mA, 17 Voperating rate <= 18000 cycles/hour no-load<= 1200 cycles/hour under loadmechanical durability 5000000 cycleselectrical durability 100000 cycles for resistive loadAverage coil consumption in VA 3 at 60 Hzdrop-out voltage threshold >= 0.15 Uc ACOperate time 20 ms at nominal voltageRelease time 20 ms at nominal voltageAverage coil resistance 290 Ohm at 20 °C +/- 15 %rated operational voltage limits 38.4...52.8 V ACprotection category RT Isafety reliability data B10d = 100000operating position Any positionproduct weight 0.086 kgdevice presentation Complete productEnvironment dielectric strength 2000 V AC between poles with basic insulation1500 V AC between contacts with micro disconnection insulation2500 V AC between coil and contact with reinforced insulationproduct certifications CSARoHSULREACHEACstandards EN/IEC 61810-1UL 508CSA C22.2 No 14ambient air temperature for storage -40...85 °Cambient air temperature for operation -40...55 °Cvibration resistance 3 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles in operation)4 gn (f = 10...150 Hz), amplitude +/- 1 mm (on 5 cycles not operating)IP degree of protection IP40pollution degree 3shock resistance 10 gn for 11 ms in operation conforming to EN/IEC 60068-2-2710 gn for 11 ms not operating conforming to EN/IEC 60068-2-27Offer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Need no specific recycling operations -
Documents and Downloads
Language- English
CatalogueSizeAdd to My DocumentsZelio Relay - Electromechanical relays Catalog (Version 3.0)CertificateSizeAdd to My DocumentsUL Recognized RPF, RSL1, RPM, RSB, RUMC, RUMF, RXM (Version 1.0)CSA Certificate RXM, RHK, RHN, RHZ, RPF (Version 1.0)UL LISTED Certificate RPM, RUMC, RUMF, RXM, RPF (Version 1.0)Declaration of conformitySizeAdd to My DocumentsEU DOC - Zelio Relay RUM RUZ (Version 1.0)Product Environmental ProfileSizeAdd to My DocumentsRPM... Zelio relays - Power Plug-in Relay, Product End-of-Life Instructions (Version 2.0)Date 7/26/18Size 10.3 MBRUM... ZELIO Universal Relay, Product Environmental Profile (Version 1.0)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Dimensions -
Connections and Schema
Wiring DiagramWiring DiagramSymbols shown in blue correspond to Nema marking.
-
Performance Curves
Electrical Durability of ContactsDurability (inductive load) = durability (resistive load) x reduction coefficient.
Resistive AC load
XSwitching capacity (kVA)YDurability (Number of operating cycles)Reduction coefficient for inductive AC load (depending on power factor cos ϕ)
YReduction coefficient (A)Maximum switching capacity on resistive DC load
XVoltage DCYCurrent DCNote : These are typical curves, actual durability depends on load, environment, duty cycle, etc.