Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

LC3D80Q7 Product picture Schneider Electric

Range: TeSys D

Star delta starter

LC3D80Q7

LC3D80Q7 Product picture Schneider Electric
Range: TeSys D

Star delta starter

LC3D80Q7

TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 380 V AC coil

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Star delta starter
    device short name
    LC3D
    contactor application
    Motor control
    utilisation category
    AC-3
    device presentation
    Pre-wired
    poles description
    3 x 3P
    power pole contact composition
    3 x 3 NO
    [Ue] rated operational voltage
    <= 690 V AC 25...400 Hz for power circuit
    [Ie] rated operational current
    80 A (<= 60 °C) AC AC-3 for power circuit at <= 440 V
    motor power kW
    37 kW at 220/230 V AC 50/60 Hz
    75 kW at 380/400 V AC 50/60 Hz
    75 kW at 415 V AC 50/60 Hz
    75 kW at 440 V AC 50/60 Hz
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    380 V AC 50/60 Hz
    auxiliary contact composition
    1 NC for KM2 line contactor
    1 NO for KM3 delta contactor
    [Uimp] rated impulse withstand voltage
    8 kV conforming to IEC 60947
    overvoltage category
    III
    [Ui] rated insulation voltage
    600 V certifications CSA power circuit
    600 V certifications UL power circuit
    600 V certifications CSA signalling circuit
    600 V certifications UL signalling circuit
    1000 V conforming to IEC 60947-4-1 power circuit
    1000 V conforming to IEC 60947-1 signalling circuit
    electrical durability
    10 Mcycles 80 A AC-3 <= 440 V
    mounting support
    Plate
    standards
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    CSA C22.2 No 14
    product certifications
    BV
    CCC
    CSA
    DNV
    GL
    GOST
    LROS (Lloyds register of shipping)
    RINA
    UL
    Complementary
    connections - terminals
    Screw clamp terminals for control circuit 1 1...4 mm² flexible without cable end
    Screw clamp terminals for control circuit 2 1...4 mm² flexible without cable end
    Screw clamp terminals for control circuit 2 1...2.5 mm² flexible with cable end
    Screw clamp terminals for control circuit 1 1...4 mm² solid without cable end
    Screw clamp terminals for control circuit 2 1...4 mm² solid without cable end
    Screw clamp terminals for power circuit 1 4...50 mm² flexible without cable end
    Screw clamp terminals for power circuit 2 4...25 mm² flexible without cable end
    Screw clamp terminals for power circuit 1 4...50 mm² flexible with cable end
    Screw clamp terminals for power circuit 2 4...16 mm² flexible with cable end
    Screw clamp terminals for power circuit 1 4...50 mm² solid without cable end
    Screw clamp terminals for power circuit 2 4...25 mm² solid without cable end
    Screw clamp terminals for control circuit 1 1...2.5 mm² flexible with cable end
    tightening torque
    1.7 N.m for control circuit screw clamp terminals flat Ø 6 mm
    1.7 N.m for control circuit screw clamp terminals Philips No 2
    9 N.m for power circuit screw clamp terminals flat Ø 6...8 mm
    mechanical durability
    4 Mcycles
    operating rate
    30 cyc/h at <= 60 °C
    starting time
    30 s
    coil technology
    Without built-in suppressor module
    control circuit voltage limits
    0.3...0.6 Uc at 55 °C drop-out 50/60 Hz
    0.8...1.1 Uc at 55 °C operational 50 Hz
    0.85...1.1 Uc at 55 °C operational 60 Hz
    inrush power in VA
    140 VA at 20 °C 0.75 60 Hz
    160 VA at 20 °C 0.75 50 Hz
    hold-in power consumption in VA
    13 VA at 20 °C 0.3 60 Hz
    15 VA at 20 °C 0.3 50 Hz
    heat dissipation
    4...5 W at 50/60 Hz
    auxiliary contacts type
    Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
    Mirror contact conforming to IEC 60947-4-1 3 x 1 NC
    signalling circuit frequency
    25...400 Hz
    minimum switching current
    For signalling circuit
    minimum switching voltage
    17 V for signalling circuit
    non-overlap time
    1.5 ms on energisation between NC and NO contact
    1.5 ms on de-energisation between NC and NO contact
    width
    311 mm
    height
    143 mm
    depth
    183 mm
    product weight
    5.2 kg
    Environment
    insulation resistance
    > 10 MOhm for signalling circuit
    IP degree of protection
    IP2x front face conforming to IEC 60529
    protective treatment
    TH conforming to IEC 60068-2-30
    pollution degree
    3
    ambient air temperature for storage
    -60...80 °C
    ambient air temperature for operation
    -40...70 °C at Uc
    operating altitude
    3000 m without derating in temperature
    fire resistance
    850 °C conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations contactor open 2 Gn, 5...300 Hz
    Shocks contactor open 8 Gn for 11 ms
    Vibrations contactor closed 3 Gn, 5...300 Hz
    Shocks contactor closed 10 Gn for 11 ms
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    End of life manual
    Date
    Size
    Add to My Documents
    Date 12/1/15
    Size 181.1 KB
    Product environmental
    Date
    Size
    Add to My Documents
    Date 9/21/17
    Size 197.1 KB
  • Technical FAQs

    No results found.