Cabling and Connection - FAQs

FAQ Search
Most Recently Published FAQs

Results 1 - 10 of 45

FAQ ID Description
FA279596What is the conduit kit part number for the ATV61 or ATV71 drive with the S6X sufffix?
Issue: What is the conduit kit part number for the ATV61 or ATV71 drive with the S6X sufffix? Product Line: Altivar 61 and ATV71 with the S6X suffix Environment: Options Cause: Needs...
FA275719What is the time delay between detecting a motor overload fault, and when power is removed from the motor on an ATV61 series drive?
Issue: What is the time delay between detecting a motor overload fault, and when power is removed from the motor on an ATV61 series drive? Product...
FA277045What is Command Switching on the ATV61/71?
Issue:  What is Command Switching on the ATV61/71?   Product Line: Altivar 61, Altivar 71   Environment: All serial numbers   Cause: N/A   Resolution: When...
FA242816How to connect the XUSL4E curtain with the obsolete pre-wired connectors used in the obsolete XUSLD/B curtain range?
XUSL4E type 4 safety light curtains and obsolete XUSLD/B light curtains use similar M12 connectors with the same pin number, on each part of the light...
FA253020What do the LED's indicate on the ATV58 devicenet card?
Issue: LED indicators   Product Line: ATV58   Environment: All models and serial numbers with VW3A58309U option card.   Cause: None   Resolution: DIAGNOSTICS Visually...
FA253218How do you convert an HOA to HOC on an enclosed E-Flex, M-Flex or MCC drive?
Issue: How  do you convert an HOA to HOC on an enclosed E-Flex, M-Flex or MCC drive? Product Line: E-Flex, M-Flex or MCC Environment: All enclosed...
FA252225Can you use the VW3A1101 keypad with the ATS48 soft starters?
Issue: Can you use the VW3A1101 keypad with the ATS48 soft starters? Product Line: Altistart ATS48 Environment: All Cause: Needs to run a 50ft...
FA163780How do you wire a external 24vdc digital output from a PLC to the input of the ATV21 or 212 drive?
Issue: How do you wire a external 24vdc digital output from a PLC to the input of the ATV21 or 212 drive? Product Line: Altivar ATV21 or ATV212 Environment: All Cause: Needs...
FA242819How to provide a signal to a pilot light or to a PLC input, in the XUSL4E/2E light curtain application?
The XUSL4E/2E safety light curtains do not integrate additional output to supply a pilot light or a PLC input. Please refer to the attached document...
FA243077How to connect the XUSL4E curtain with the obsolete pre-wired connectors used in the obsolete XUSLP equivalent curtain range, for its replacement?
XUSL4E type 4 safety light curtains and obsolete XUSLP equivalent light curtains use similar M12 connectors with the same pin number, on each part...