Narrow By
  1. Your SelectionRemove All

Cabling and Connection - FAQs

FAQ Search
Most Recently Published FAQs

Results 1 - 10 of 25

FAQ ID Description
FA12170What is the maximum motor cable length allowed for Altivar 11 Drive.
The maximum motor cable length allowed for Altivar 11 Drive is as follows:  50 meters -- Shielded cable  100 meters -- Non-Shielded cable
FA12203Can the Multi 9 range MCB be reverse fed.
Yes, the Multi9 miniature circuit breakers (MCBs) can be fed either from top or bottom without any deterioration of their characteristics.   Refer...
FA232984APC Switched Rack PDUs - any pending outlet commands are lost when PDU Network Management Interface is rebooted
Issue If an APC Switched Rack PDU's Network Management Interface is rebooted (manually by the user, or automatically due to network watchdog timer...
FA231199Are there Windows or Linux drivers for the NBAC0226 USB to serial cable.
Issue: There are no drivers available for the NBAC0226 serial to USB cable. Product Line: NetBotz Environment: NetBotz Serial devices...
FA226483KVM1116P, KVM2116P, and KVM2132P KVM Switches using standalone WinClient and Java Client - Compatibility/Video Issue
Issue When using the WinClient or Java Client with my KVM1116P, KVM2116P or KVM2132P IP KVM Switch, why is my video distorted (as seen below)? Product...
FA21083What is the insulation voltage rating for cables BMX FTW and BMX FCW in Modicon M340 range.
The dielectric withstanding (VDC) for cables BMX FTW and BMX FCW is 1000 Volts applied for 1 minute and th minimum specific insulation resistance...
FA12217Can TeSys range overload relays be used in DC application.
The overload relay with the bimetal technology (Thermal Overload) only can be used in DC application. Tesys LRD RangeTesys LRD thermal overload relays...
FA12219How to mount the Rectifier DR5TE on TeSys F range of contactor.
The DR5TE4U rectifier is mounted separately off the coil on a little support sold with the coil. Refer attachment for the mounting instruction of...
FA12215Can TeSys T be used downstream of Altivar range Variable Speed Drive.
The Current Transformers (CTs) of TeSys T are deigned to work under the frequency range between 47 to 63 Hz only. However, the output frequency range...
FA12213Is it possible to use TeSys GV2 and TeSys GV3 Range MPCB in DC applications.
The TeSys GV2 and TeSys GV3 range MPCB can be used in DC applications as per their technical specifications.  Refer the below wiring connection for...

Results 1 - 10 of 25