Narrow By
  1. Your SelectionAll

Cabling and Connection - FAQs

FAQ Search
Most Recently Published FAQs

Results 1 - 10 of 23

FAQ ID Description
FA226483KVM1116P, KVM2116P, and KVM2132P KVM Switches using standalone WinClient and Java Client - Compatibility/Video Issue
Issue When using the WinClient or Java Client with my KVM1116P, KVM2116P or KVM2132P IP KVM Switch, why is my video distorted (as seen below)? Product...
FA21083What is the insulation voltage rating for cables BMX FTW and BMX FCW in Modicon M340 range.
The dielectric withstanding (VDC) for cables BMX FTW and BMX FCW is 1000 Volts applied for 1 minute and th minimum specific insulation resistance...
FA12217Can TeSys range overload relays be used in DC application.
The overload relay with the bimetal technology (Thermal Overload) only can be used in DC application. Tesys LRD RangeTesys LRD thermal overload relays...
FA12219How to mount the Rectifier DR5TE on TeSys F range of contactor.
The DR5TE4U rectifier is mounted separately off the coil on a little support sold with the coil. Refer attachment for the mounting instruction of...
FA12215Can TeSys T be used downstream of Altivar range Variable Speed Drive.
The Current Transformers (CTs) of TeSys T are deigned to work under the frequency range between 47 to 63 Hz only. However, the output frequency range...
FA12213Is it possible to use TeSys GV2 and TeSys GV3 Range MPCB in DC applications.
The TeSys GV2 and TeSys GV3 range MPCB can be used in DC applications as per their technical specifications.  Refer the below wiring connection for...
FA12212Is it permissible to electrically reverse feed the TeSys range of MPCB.
Yes, it is possible to reverse feed the Power in the TeSys GV range of Motor protection circuit breaker (MPCB).  It means you can connect the incoming...
FA12214What is the maximum length of the connector cable between the LTMR and LTME module in TeSys T Range.
Three different length connectors are available for connecting the LTMR and LTME module.The maximum length between the connections of TeSys T controller...
FA12187Is it possible to give Start/Stop commands from PLC via Modbus Port on LUCM module of TeSys U.
You can connect the Modbus port of LUCM module (Multi Functional Control Unit) of TeSys U controller with PLC in order to access all the registers,...
FA12178What is the maximum cable length allowed between PC and TeSys T for connection via PowerSuite.
The maximum cable length allowed between PC and TeSys T connection via PowerSuite depends on the system and the converter used.If the standard converter,...

Results 1 - 10 of 23